NEULOG CONDUCTIVITY FIELD SENSOR GUIDE
NeuLog conductivity sensor
NUL-215 Carolina # 369644
The NeuLog Conductivity Sensor can be used for any science experiment or activity
which utilizes liquid samples that can conduct electrical currents such as in the fields
of Chemistry, Biology, Earth Science, Environmental Science, Biochemistry, Physics,
etc.
Electrical conductivity is a material property measured by how easily it is able to
conduct electrical currents. A current is the flow of electrical charge (electrons)
through ions in a material. This sensor is designed for detecting electrical currents
specifically with liquid solutions.
The sensor comes pre-calibrated so you can start experimentation right out of the box
using any of the following guides. There are three units in which data can be
collected: μs/cm – micro Siemens per centimeter, mg/L milli gram per liter, and ppm
parts per million.
Just a few of the thousands of possible experiments that can be done with the NUL-
215 sensors are: Monitoring of ecological systems, chemical analysis and
identification, environmental health testing, water quality testing, etc.
Probe usage and care:
The probe has two flat electrodes with known surface areas and distance between
them. A signal is supplied to the electrodes and by testing the signal behavior, the
conductivity of the solution is calculated.
General care:
Avoid touching the probes flat green surface if possible.
Never submerge the probes plastic body in any liquid.
Gently rinse the probe off with distilled water after each use and between
samples to avoid damage and contamination.
Handle and store with care to avoid damaging or chipping the probe.
Quick start procedure:
PC or Mac Computer
Materials needed:
NUL-215 Conductivity Sensor
USB-200 USB Module
A USB to mini USB cable (which comes with the USB-200)
Your conductivity sensor needs to be connected to a USB-200 module. The USB-200
module then connects to a computer via a USB to mini-USB cable. Please note that
you cannot plug the conductivity sensor directly into the computer.
Resident PC software and browser based software can be downloaded for free at
www.NeuLog.com/dowload as well as a full software user guide. Note: Make sure not
to download and install both types of software, they will conflict on the computer.
Procedure:
1. Install the NeuLog software
2. Connect the USB-200 module to the PC or Mac
3. Connect the conductivity sensor to the USB-200 module (they directly plug
together). Please note there is no calibration required for this sensor.
4. Open the NeuLog software.
5. Once a conductivity sensor logo appears on the left side of the screen the
probe has been automatically identified and you can begin experimentation.
6. If the conductivity sensor is not automatically identified then click the
“Search for sensors” icon to find the sensor.
7. Select the “On-line experiment” button; this will open a graph below.
8. Click on the “Module setup” button located on the conductivity sensor icon in
the module window to change the sensor settings if need be.
9. Click on the experiment set up button to change the experiment settings if
need be (experiment duration for example).
10. The conductivity sensor will give a live reading in the box to the left of the
screen while plugged in.
11. To run an experiment and collect data click “Run experiment”.
12. To end data collection early, click “Stop experiment”.
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1

NEULOG CONDUCTIVITY FIELD SENSOR GUIDE NeuLog conductivity sensor NUL-215 Carolina # 369644 The NeuLog Conductivity Sensor can be used for any sc

Page 2

NEULOG CONDUCTIVITY FIELD SENSOR GUIDE Tablet, smart phone device Materials needed:  NUL-215 Conductivity Sensor  WIFI-201 WIFI module  BAT-

Page 3

NEULOG CONDUCTIVITY FIELD SENSOR GUIDE Procedure: 1. Connect the conductivity sensor directly to the left side of a charged BAT-200 module. 2. Wh

Page 4

NEULOG CONDUCTIVITY FIELD SENSOR GUIDE On the conductivity probe there are two electrodes of known surface area with a known distance between them w